triocentre.blogg.se

Protel 99se
Protel 99se







protel 99se

Supplement: If ADVPCB99SE.INI and ADVSCH99SE.INI are opened with Notepad, the modification can not be saved, it should be that the corresponding file modification permission is not opened. A NOP instruction is 90 in hexadecimal, hence the change. Change all bytes from offset 2690E to 26917 ( a total of 10 bytes that need to be changed) to 90. (Note that you must ensure that the protel99se program is closed each time you modify it, otherwise you will change it for nothing, because Protel will modify these two files when it exits.) So: get yourself a hex editor (I use 'HxD', it's free) and edit the 'Client99SE.exe' file. After modification, open PROTEL 99SE again, OK. It was changed according to its original expression.Ĥ. The path at that time was: E:\self-written materials\Protel 99 SE\self-made components\component library.ddb\PCB.LIB. Note: file3 is a PCB package library made by myself.

protel 99se

I made the following changes to work:įile0=D>MSACCESS:$RP>d:\Program Files\Design Explorer 99 SE\Library\Pcb\Generic Footprints$RN>Advpcb.ddb$OP>$ON>PCB Footprints.lib$ID>-1$ATTR> 0$E>PCBLIB$STF>įile1=D>MSACCESS:$RP>d:\Program Files\Design Explorer 99 SE\Library\Pcb\Generic Footprints$RN>Transformers.ddb$OP>$ON>Transformers.lib$ID>25$ATTR>0$ E>PCBLib$STF>įile2=D>MSACCESS:$RP>d:\Program Files\Design Explorer 99 SE\Library\Pcb\Generic Footprints$RN>Transistors.ddb$OP>$ON>Transistors.lib$ID>25$ATTR>0$ E>PCBLib$STF>įile3=D>MSACCESS:$RP>E:\self-written data\Protel 99 SE\home-made components$RN>component library.ddb$OP>$ON>PCB.LIB$ID>85$ATTR>0$E>PCBLIB $STF> The design has duplicate circuits within it i.e 11. The same is feasible after the windows7 system is changed. I have created a design accross several sheets and one master sheet in schematic entry which was fine. Also change ADVPCB99SE.INI to configure PCB library. and so on, but pay attention to the last modification of the Count property on File0, if you add two, change its value to 2.įile0=d:\Program Files\Design Explorer 99 SE\Library\Sch\Miscellaneous Devices.ddbįile1=d:\Program Files\Design Explorer 99 SE\Library\Sch\Protel DOS Schematic Libraries.ddbįile2=d:\Program Files\Design Explorer 99 SE\Library\Sch\Intel Databooks.ddbįile3=d:\Program Files\Design Explorer 99 SE\Examples\Backup of AT89C2051.Libģ.

protel 99se

Open the ADVSCH99SE.INI file with Note, find File0 under, the content after the equal sign is the library that has been added by default, what if you want to add more than one? Simple, add File1 after File0, File2. Enter C\WINDOWS and find two files ADVPCB99SE.INI and ADVSCH99SE.INI Ģ.









Protel 99se